AVM System 550G
Aussie Skin 550® is a heavy-duty, puncture-resistant sheet waterproofing membrane designed for easy installation. Enhanced with advanced technologies, it achieves strong adhesion to wet concrete or shotcrete. Upon curing, the membrane forms a fully bonded seal to the concrete surface, effectively preventing any potential water migration between the membrane and the substrate.
Where to Use
- Retaining walls
- Shotcrete walls
- Basements
- Under-slabs
- Mud-slabs
- Permanent formwork (e.g., lagging)
- Existing back-filled structural walls
- Smoothly prepared concrete substrates
- Compacted earth or crushed stone substrates
Key Features
- Permanent Bond to Concrete — Ensures a continuous waterproofing barrier by forming an integral bond with poured concrete.
- Puncture Resistant — Durable HDPE layer withstands construction-related stresses and protects against damage.
- Easy Installation — Designed for straightforward application, reducing labor time and costs.
- Cost-Effective System — Provides long-term waterproofing protection at a competitive price.
Material
- Sheet Product (Pre-applied HDPE membrane)
System
- Pre-Applied Below-Grade Waterproofing System
Installation
- See Installation Instructions for warnings, installation instructions and information on various application surfaces.
Documents
- Approvals
- Technical Bulletins
- Specifications
- Details
0550G – View-ALL (PDF)
Post Applied Walls
- 0550G_0560G.0002 SLAB ON GRADE OVER AUSSIE SKIN, CONCRETE WALLS 500_502 (DWG) (PDF)
- 0550G_0560G.0004 SLAB ON GRADE WITH FOOTING OVER AUSSIE SKIN, CONCRETE WALLS AUSSIE MATE (DWG) (PDF)
- 0550G_0560G.0006 SLAB ON GRADE OVER AUSSIE SKIN, CONCRETE WALLS 520 (DWG) (PDF)
- 0550G_0560G.0008 SLAB ON GRADE OVER AUSSIE SKIN CMU BLOCK WALLS 500_502 (DWG) (PDF)
- 0550G_0560G.0010 SLAB ON GRADE OVER AUSSIE SKIN CMU BLOCK WALLS 520 (DWG) (PDF)
- 0550G_0560G.0012 SLAB ON GRADE OVER AUSSIE SKIN CONCRETE WALLS MINIMAL EXPOSED FOOTING 500_502 (DWG) (PDF)
- 0550G_0560G.0014 SLAB ON GRADE OVER AUSSIE SKIN CONCRETE WALLS MINIMAL EXPOSED FOOTING 520 (DWG) (PDF)
- 0550G_0560G.0016 ELEVATED SLAB OVER AUSSIE SKIN CONCRETE WALLS 500_502 (DWG) (PDF)
- 0550G_0560G.0018 ELEVATED SLAB OVER AUSSIE SKIN CONCRETE WALLS 520 (DWG) (PDF)
- 0550G_0560G.0020 ELEVATED SLAB OVER AUSSIE SKIN CONCRETE WALLS AUSSIE MATE (DWG) (PDF)
- 0550G_0560G.0022 AUSSIE MEMBRANE INSTALLATION OVER AUSSIE SKIN (DWG) (PDF)
Slab Wall Transition
- 0550G_0560G.1200 TYPICAL LAGGING WALL (DWG) (PDF)
- 0550G_0560G.1210 BLINDSIDE LAGGING SLAB TO WALL TRANSITION (DWG) (PDF)
- 0550G_0560G.1212 BLINDSIDE LAGGING SLAB TO WALL TRANSITION, INSULATION (DWG) (PDF)
- 0550G_0560G.1220 LAGGING WALL WITH ROCK POCKET (DWG) (PDF)
- 0550G_0560G.1224 RAISED SLAB NON-HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.1225 RAISED SLAB, SHOTCRETE RETAINING WALL, NON-HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.1228 RAISED SLAB WITH VAPOR BARRIER (DWG) (PDF)
- 0550G_0560G.1229 Transition to Vapor Barrier Underslab (DWG) (PDF)
- 0550G_0560G.1230 MAT SLAB WITH UNDERSLAB DRAINAGE (DWG) (PDF)
- 0550G_0560G.1240 TYPICAL METAL SHEET PILE RETAINING WALL (DWG) (PDF)
- 0550G_0560G.1242 TYPICAL SHOTCRETE RETAINING WALL (DWG) (PDF)
- 0550G_0560G.1244 SHEET PILE RETAINING WALL (DWG) (PDF)
- 0550G_0560G.3000 ELEVATOR PIT OVER AUSSIE SKIN (DWG) (PDF)
Tie Back & Soldier Piles
- 0550G_0560G.1530 METAL TIE-BACK COVER (DWG) (PDF)
- 0550G_0560G.1531 DETENSIONED TIE-BACK (DWG) (PDF)
- 0550G_0560G.1532 4 INCH TIE-BACK COVER (DWG) (PDF)
- 0550G_0560G.1533 6 INCH TIE-BACK COVER (DWG) (PDF)
- 0550G_0560G.1534 8 INCH TIE-BACK COVER (DWG) (PDF)
- 0550G_0560G.1535 DETENTIONED TIE BACK OPTION 2 (DWG) (PDF)
- 0550G_0560G.1536 WALL PIPE RAKER (DWG) (PDF)
- 0550G_0560G.1537 WALL I-BEAM RAKER (DWG) (PDF)
- 0550G_0560G.1540 BACK LAGGED SOLDIER PILE (DWG) (PDF)
- 0550G_0560G.1542 – Mid Lagged Soldier Pile (DWG) (PDF)
- 0550G_0560G.1544 CEMENT BOARD AT GRADE (DWG) (PDF)
Grade Beams & Pile Caps
- 0550G_0560G.2610 PILE CAP DETAIL – HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.2615 – Extended Pile Cap Detail – Hydrostatic Option 2 (DWG) (PDF)
- 0550G_0560G.2630 PILE CAP DETAIL NON HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.2550 AUSSIE SKIN OVER GRADE-BEAM NON-HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.2540 AUSSIE SKIN OVER GRADE-BEAM HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.2500 AUSSIE SKIN UNDER GRADE BEAM HYDROSTATIC (DWG) (PDF)
Penetrations
- 0550G_0560G.2800 PIPE RAKER IN SLAB (DWG) (PDF)
- 0550G_0560G.2802 AUSSIE SKIN PIPE BANK PITCH PAN (DWG) (PDF)
- 0550G_0560G.2804 SLAB PENETRATION (SINGLE) (DWG) (PDF)
- 0550G_0560G.2806 WELL PIPE SEALING BOXOUT (DWG) (PDF)
- 0550G_0560G.2808 – Slab Tie Penetration (DWG) (PDF)
- 0550G_0560G.2810 – AUSSIE SKIN UNDERSLAB REPAIR (DWG) (PDF)
- 0550G_0560G.4000 THROUGH WALL PENETRATION SINGLE SYSTEM, SEALANT ON SANDED SIDE (DWG) (PDF)
- 0550G_0560G.4002 MULTIPLE THROUGH WALL PENETRATION SINGLE SYSTEM, SEALANT ON SANDED SIDE (DWG) (PDF)
- 0550G_0560G.4003 Verical Pitch Pan – Pre Applied (DWG) (PDF)
- 0550G_0560G.4004 Vertical Pitch Pan – Post Applied (DWG) (PDF)
- 0550G_0560G.4005 SLEEVED PIPE PENETRATION (DWG) (PDF)
- 0550G_0560G.4010 CORED PENETRATION, SEALANT ON HDPE SIDE (DWG) (PDF)
- 0550G_0560G.4015 – Cored Penetration (DWG) (PDF)
Laps, Fasteners & Corners
- 0550G_0560G.4100 REBAR TIE (DWG) (PDF)
- 0550G_0560G.4102 EYE LAG SCREW (DWG) (PDF)
- 0550G_0560G.4200 NON-FLUSH FASTENER (DWG) (PDF)
- 0550G_0560G.4205 NAIL SCREW DETAIL (DWG) (PDF)
- 0550G.6000 FACTORY LAP DETAILING (DWG) (PDF)
- 0550G.6002 NON-FACTORY LAP DETAILING (DWG) (PDF)
- 0550G.6004 NON-FACTORY LAP WITH DETAIL STRIP (DWG) (PDF)
- 0550G_0560G.6005 LAPPING DETIAL WITH AUSSIE SEAL M AND SANDED TAPE (DWG) (PDF)
- 0550G_0560G.6006 FACTORY LAPS IN SHORTCRETE HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.6007 NON-FACTORY LAPS IN SHORTCRETE HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.6008 NON-FACTORY LAPS IN SHORTCRETE HYDROSTATIC (HEAT) (DWG) (PDF)
- 0550G_0560G.6010 T-LAP DETAIL (DWG) (PDF)
- 0550G.6015 STANDARD OVERLAP SPACING (DWG) (PDF)
- 0550G_0560G.6020 UNDER SLAB ASSEMBLY (DWG) (PDF)
- 0550G_0560G.6200 INSIDE CORNER DETAIL (DWG) (PDF)
- 0550G_0560G.6210 Inside Corner (DWG) (PDF)
- 0550G_0560G.6260 OUTSIDE CORNER DETAIL AT BOTTOM OF WALL (DWG) (PDF)
- 0550G_0560G.6265 Outside Corner Detail at Top of Wall (DWG) (PDF)
- 0550G_0560G.8002 Repair Procedure for Large Areas (DWG) (PDF)
- 0550G_0560G.8004 Repair Procedure for Cuts and Slices (DWG) (PDF)
Transitions & Terminations
- 0550G_0560G.7000 GRADE TRANSITION TO AUSSIE MATE (DWG) (PDF)
- 0550G_0560G.7010 AUSSIE SKIN LAGGING TO AUSSIE MATE FREE STANDING (DWG) (PDF)
- 0550G_0560G.7020 AUSSIE SKIN INSTALLATION OVER AUSSIE MEMBRANE 500_502_520 (DWG) (PDF)
- 0550G_0560G.7022 Aussie Skin Underslab Transition to Aussie Mate – Option 1 (DWG) (PDF)
- 0550G_0560G.7024 Aussie Skin Underslab Transition to Aussie Mate – Option 2 (DWG) (PDF)
- 0550G_0560G.7500 TERMINATION AT GRADE – OPTION 1 (DWG) (PDF)
- 0550G_0560G.7505 TERMINATION AT GRADE – OPTION 2 (DWG) (PDF)
Aussie Clay 550 Dual System
- 0550G_0560G – Aussie Dual System – View-ALL (PDF)
- 0550G_0560G-1226AC – Aussie Dual System – Raised Slab Slab_Underslab Drainage_Full Wrap (DWG) (PDF)
- 0550G_0560G-1200AC – Aussie Dual System Typical Lagging Wall (DWG) (PDF)
- 0550G_0560G-1212AC – Aussie Dual System Over Lagging (DWG) (PDF)
- 0550G_0560G-1214AC – Aussie Dual System Over Concrete (DWG) (PDF)
- 0550G_0560G-1220AC – Aussie Dual System Over Lagging – Rock Pocket (DWG) (PDF)
- 0550G_0560G-1221AC – Aussie Dual System with Aussie Clay Underslab – Rock Pocket (DWG) (PDF)
- 0550G_0560G-1226AC – Aussie Dual System – Raised Slab Slab_Underslab Drainage_Full Wrap (DWG) (PDF)
- 0550G_0560G-1530AC – Aussie Dual System – Metal Tieback Cover (DWG) (PDF)
- 0550G_0560G-1531AC – Aussie Dual System Detensioned Tie Back (DWG) (PDF)
- 0550G_0560G-1532AC – Aussie Dual System – 4 Inch Tie Back Cover (DWG) (PDF)
- 0550G_0560G-1533AC – Aussie Dual System – 6 Inch Tie Back Cover (DWG) (PDF)
- 0550G_0560G-1534AC – Aussie Dual System – 8 Inch Tie Back Cover (DWG) (PDF)
- 0550G_0560G-1536AC – Aussie Dual System – Wall Pipe Raker (DWG) (PDF)
- 0550G_0560G-1540AC – Aussie Dual System – Back Lagged Soldier Pile (DWG) (PDF)
- 0550G_0560G-1544AC – Aussie Dual System – Cement Board at Grade (DWG) (PDF)
- 0550G_0560G-4000AC – Aussie Dual System – Penetration Through Wall (DWG) (PDF)
- 0550G_0560G-4002AC – Aussie Dual System – Multiple Penetrations Through Wall (DWG) (PDF)
- 0550G_0560G-4005AC – Aussie Dual System – Sleeved Pipe Penetration (DWG) (PDF)
- 0550G_0560G-4010AC – Aussie Dual System – Cored Penetration Sealant on HDPE Side (DWG) (PDF)
- 0550G_0560G-4100AC – Aussie Dual System – Rebar Tie (DWG) (PDF)
- 0550G_0560G-7502AC – Aussie Dual System – Grade Termination 01 (DWG) (PDF)
- 0550G_0560G-7505AC – Aussie Dual System – Grade Termination 02 (DWG) (PDF)
Technical Data Sheet
Safety Data Sheet
Gallery