AVM System 560G
Aussie Skin 560G is a heavy-duty, pre-applied 2.0 mm thick waterproofing membrane designed for methane resistance and shotcrete applications. This robust HDPE sheet membrane is engineered for easy installation and superior puncture resistance. Advanced technologies enable exceptional adhesion between the membrane and wet concrete or shotcrete. Once cured, the membrane forms a fully bonded seal to the concrete surfaces, effectively preventing water migration between the membrane and the concrete.
Where to Use
- Retaining walls
- Shotcrete walls
- Basements
- Under-slabs
- Mud-slabs
- Methane and VOC Systems
- Permanent formwork (e.g., lagging)
- Existing back-filled structural walls
- Smoothly prepared concrete substrates
- Compacted earth or crushed stone substrates
Key Features
- Permanent Bond to Concrete — Ensures a continuous waterproofing barrier by forming an integral bond with poured concrete.
- Puncture Resistant — Durable HDPE layer withstands construction-related stresses and protects against damage.
- Easy Installation — Designed for straightforward application, reducing labor time and costs.
- Cost-Effective System — Provides long-term waterproofing protection at a competitive price.
Material
- Sheet Product (Pre-applied HDPE membrane)
System
- Pre-Applied Below-Grade Waterproofing System
Installation
- See Installation Instructions for warnings, installation instructions and information on various application surfaces.
Documents
- Approvals
- Technical Bulletins
- Specifications
- Details
Post Applied Walls
- 0550G_0560G.0002 SLAB ON GRADE OVER AUSSIE SKIN, CONCRETE WALLS 500_502 (DWG) (PDF)
- 0550G_0560G.0004 SLAB ON GRADE WITH FOOTING OVER AUSSIE SKIN, CONCRETE WALLS AUSSIE MATE (DWG) (PDF)
- 0550G_0560G.0006 SLAB ON GRADE OVER AUSSIE SKIN, CONCRETE WALLS 520 (DWG) (PDF)
- 0550G_0560G.0008 SLAB ON GRADE OVER AUSSIE SKIN CMU BLOCK WALLS 500_502 (DWG) (PDF)
- 0550G_0560G.0010 SLAB ON GRADE OVER AUSSIE SKIN CMU BLOCK WALLS 520 (DWG) (PDF)
- 0550G_0560G.0012 SLAB ON GRADE OVER AUSSIE SKIN CONCRETE WALLS MINIMAL EXPOSED FOOTING 500_502 (DWG) (PDF)
- 0550G_0560G.0014 SLAB ON GRADE OVER AUSSIE SKIN CONCRETE WALLS MINIMAL EXPOSED FOOTING 520 (DWG) (PDF)
- 0550G_0560G.0016 ELEVATED SLAB OVER AUSSIE SKIN CONCRETE WALLS 500_502 (DWG) (PDF)
- 0550G_0560G.0018 ELEVATED SLAB OVER AUSSIE SKIN CONCRETE WALLS 520 (DWG) (PDF)
- 0550G_0560G.0020 ELEVATED SLAB OVER AUSSIE SKIN CONCRETE WALLS AUSSIE MATE (DWG) (PDF)
- 0550G_0560G.0022 AUSSIE MEMBRANE INSTALLATION OVER AUSSIE SKIN (DWG) (PDF)
Slab Wall Transition
- 0550G_0560G.1200 TYPICAL LAGGING WALL (DWG) (PDF)
- 0550G_0560G.1210 BLINDSIDE LAGGING SLAB TO WALL TRANSITION (DWG) (PDF)
- 0550G_0560G.1212 BLINDSIDE LAGGING SLAB TO WALL TRANSITION, INSULATION (DWG) (PDF)
- 0550G_0560G.1220 LAGGING WALL WITH ROCK POCKET (DWG) (PDF)
- 0550G_0560G.1224 RAISED SLAB NON-HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.1225 RAISED SLAB, SHOTCRETE RETAINING WALL, NON-HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.1228 RAISED SLAB WITH VAPOR BARRIER (DWG) (PDF)
- 0550G_0560G.1229 Transition to Vapor Barrier Underslab (DWG) (PDF)
- 0550G_0560G.1230 MAT SLAB WITH UNDERSLAB DRAINAGE (DWG) (PDF)
- 0550G_0560G.1240 TYPICAL METAL SHEET PILE RETAINING WALL (DWG) (PDF)
- 0550G_0560G.1242 TYPICAL SHOTCRETE RETAINING WALL (DWG) (PDF)
- 0550G_0560G.1244 SHEET PILE RETAINING WALL (DWG) (PDF)
- 0550G_0560G.3000 ELEVATOR PIT OVER AUSSIE SKIN (DWG) (PDF)
Tie Back & Soldier Piles
- 0550G_0560G.1530 METAL TIE-BACK COVER (DWG) (PDF)
- 0550G_0560G.1531 DETENSIONED TIE-BACK (DWG) (PDF)
- 0550G_0560G.1532 4 INCH TIE-BACK COVER (DWG) (PDF)
- 0550G_0560G.1533 6 INCH TIE-BACK COVER (DWG) (PDF)
- 0550G_0560G.1534 8 INCH TIE-BACK COVER (DWG) (PDF)
- 0550G_0560G.1535 DETENTIONED TIE BACK OPTION 2 (DWG) (PDF)
- 0550G_0560G.1536 WALL PIPE RAKER (DWG) (PDF)
- 0550G_0560G.1537 WALL I-BEAM RAKER (DWG) (PDF)
- 0550G_0560G.1540 BACK LAGGED SOLDIER PILE (DWG) (PDF)
- 0550G_0560G.1542 – Mid Lagged Soldier Pile (DWG) (PDF)
- 0550G_0560G.1544 CEMENT BOARD AT GRADE (DWG) (PDF)
Grade Beams & Pile Caps
- 0550G_0560G.2610 PILE CAP DETAIL – HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.2615 – Extended Pile Cap Detail – Hydrostatic Option 2 (DWG) (PDF)
- 0550G_0560G.2630 PILE CAP DETAIL NON HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.2550 AUSSIE SKIN OVER GRADE-BEAM NON-HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.2540 AUSSIE SKIN OVER GRADE-BEAM HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.2500 AUSSIE SKIN UNDER GRADE BEAM HYDROSTATIC (DWG) (PDF)
Penetrations
- 0550G_0560G.2800 PIPE RAKER IN SLAB (DWG) (PDF)
- 0550G_0560G.2802 AUSSIE SKIN PIPE BANK PITCH PAN (DWG) (PDF)
- 0550G_0560G.2804 SLAB PENETRATION (SINGLE) (DWG) (PDF)
- 0550G_0560G.2806 WELL PIPE SEALING BOXOUT (DWG) (PDF)
- 0550G_0560G.2808 – Slab Tie Penetration (DWG) (PDF)
- 0550G_0560G.2810 – AUSSIE SKIN UNDERSLAB REPAIR (DWG) (PDF)
- 0550G_0560G.4000 THROUGH WALL PENETRATION SINGLE SYSTEM, SEALANT ON SANDED SIDE (DWG) (PDF)
- 0550G_0560G.4002 MULTIPLE THROUGH WALL PENETRATION SINGLE SYSTEM, SEALANT ON SANDED SIDE (DWG) (PDF)
- 0550G_0560G.4003 Verical Pitch Pan – Pre Applied (DWG) (PDF)
- 0550G_0560G.4004 Vertical Pitch Pan – Post Applied (DWG) (PDF)
- 0550G_0560G.4005 SLEEVED PIPE PENETRATION (DWG) (PDF)
- 0550G_0560G.4010 CORED PENETRATION, SEALANT ON HDPE SIDE (DWG) (PDF)
- 0550G_0560G.4015 – Cored Penetration (DWG) (PDF)
Laps, Fasteners & Corners
- 0550G_0560G.4100 REBAR TIE (DWG) (PDF)
- 0550G_0560G.4102 EYE LAG SCREW (DWG) (PDF)
- 0550G_0560G.4200 NON-FLUSH FASTENER (DWG) (PDF)
- 0550G_0560G.4205 NAIL SCREW DETAIL (DWG) (PDF)
- 0550G.6000 FACTORY LAP DETAILING (DWG) (PDF)
- 0550G.6002 NON-FACTORY LAP DETAILING (DWG) (PDF)
- 0550G.6004 NON-FACTORY LAP WITH DETAIL STRIP (DWG) (PDF)
- 0550G_0560G.6005 LAPPING DETIAL WITH AUSSIE SEAL M AND SANDED TAPE (DWG) (PDF)
- 0550G_0560G.6006 FACTORY LAPS IN SHORTCRETE HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.6007 NON-FACTORY LAPS IN SHORTCRETE HYDROSTATIC (DWG) (PDF)
- 0550G_0560G.6008 NON-FACTORY LAPS IN SHORTCRETE HYDROSTATIC (HEAT) (DWG) (PDF)
- 0550G_0560G.6010 T-LAP DETAIL (DWG) (PDF)
- 0550G.6015 STANDARD OVERLAP SPACING (DWG) (PDF)
- 0550G_0560G.6020 UNDER SLAB ASSEMBLY (DWG) (PDF)
- 0550G_0560G.6200 INSIDE CORNER DETAIL (DWG) (PDF)
- 0550G_0560G.6210 Inside Corner (DWG) (PDF)
- 0550G_0560G.6260 OUTSIDE CORNER DETAIL AT BOTTOM OF WALL (DWG) (PDF)
- 0550G_0560G.6265 Outside Corner Detail at Top of Wall (DWG) (PDF)
- 0550G_0560G.8002 Repair Procedure for Large Areas (DWG) (PDF)
- 0550G_0560G.8004 Repair Procedure for Cuts and Slices (DWG) (PDF)
Transitions & Terminations
- 0550G_0560G.7000 GRADE TRANSITION TO AUSSIE MATE (DWG) (PDF)
- 0550G_0560G.7010 AUSSIE SKIN LAGGING TO AUSSIE MATE FREE STANDING (DWG) (PDF)
- 0550G_0560G.7020 AUSSIE SKIN INSTALLATION OVER AUSSIE MEMBRANE 500_502_520 (DWG) (PDF)
- 0550G_0560G.7022 Aussie Skin Underslab Transition to Aussie Mate – Option 1 (DWG) (PDF)
- 0550G_0560G.7024 Aussie Skin Underslab Transition to Aussie Mate – Option 2 (DWG) (PDF)
- 0550G_0560G.7500 TERMINATION AT GRADE – OPTION 1 (DWG) (PDF)
- 0550G_0560G.7505 TERMINATION AT GRADE – OPTION 2 (DWG) (PDF)
Aussie Clay 560 Dual System
- 0550G_0560G – Aussie Dual System – View-ALL (PDF)
- 0550G_0560G-1226AC – Aussie Dual System – Raised Slab Slab_Underslab Drainage_Full Wrap (DWG) (PDF)
- 0550G_0560G-1200AC – Aussie Dual System Typical Lagging Wall (DWG) (PDF)
- 0550G_0560G-1212AC – Aussie Dual System Over Lagging (DWG) (PDF)
- 0550G_0560G-1214AC – Aussie Dual System Over Concrete (DWG) (PDF)
- 0550G_0560G-1220AC – Aussie Dual System Over Lagging – Rock Pocket (DWG) (PDF)
- 0550G_0560G-1221AC – Aussie Dual System with Aussie Clay Underslab – Rock Pocket (DWG) (PDF)
- 0550G_0560G-1226AC – Aussie Dual System – Raised Slab Slab_Underslab Drainage_Full Wrap (DWG) (PDF)
- 0550G_0560G-1530AC – Aussie Dual System – Metal Tieback Cover (DWG) (PDF)
- 0550G_0560G-1531AC – Aussie Dual System Detensioned Tie Back (DWG) (PDF)
- 0550G_0560G-1532AC – Aussie Dual System – 4 Inch Tie Back Cover (DWG) (PDF)
- 0550G_0560G-1533AC – Aussie Dual System – 6 Inch Tie Back Cover (DWG) (PDF)
- 0550G_0560G-1534AC – Aussie Dual System – 8 Inch Tie Back Cover (DWG) (PDF)
- 0550G_0560G-1536AC – Aussie Dual System – Wall Pipe Raker (DWG) (PDF)
- 0550G_0560G-1540AC – Aussie Dual System – Back Lagged Soldier Pile (DWG) (PDF)
- 0550G_0560G-1544AC – Aussie Dual System – Cement Board at Grade (DWG) (PDF)
- 0550G_0560G-4000AC – Aussie Dual System – Penetration Through Wall (DWG) (PDF)
- 0550G_0560G-4002AC – Aussie Dual System – Multiple Penetrations Through Wall (DWG) (PDF)
- 0550G_0560G-4005AC – Aussie Dual System – Sleeved Pipe Penetration (DWG) (PDF)
- 0550G_0560G-4010AC – Aussie Dual System – Cored Penetration Sealant on HDPE Side (DWG) (PDF)
- 0550G_0560G-4100AC – Aussie Dual System – Rebar Tie (DWG) (PDF)
- 0550G_0560G-7502AC – Aussie Dual System – Grade Termination 01 (DWG) (PDF)
- 0550G_0560G-7505AC – Aussie Dual System – Grade Termination 02 (DWG) (PDF)
Technical Data Sheet
Safety Data Sheet
Gallery